Home Up Call me back Contents Immunology Infectious agents Cellular Biology Molecular biology Instruments Chimical Product NEW antibodiesSuperoxide Dismutase (SOD) Detection Kit Nitric Oxide Synthase Detection Kit Hydroxyl (OH)/ Peroxynitrite (ONOO-)Detection Kit Fluoro H202 Hydroxyl (OH)/ Peroxynitrite (ONOO-)Detection Kit

Google

       Pricelist 2010 

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany

52074 Aachen, Germany

 Tel 0241 40 08 90 86

Fax 0241 55 91 05 36

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 51 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

Hydroxyl / Peroxynitrite Detection Kit
Fluorescent Hydroxyl (•OH) / Peroxynitrite (ONOO -) Detection Kit
Key Benefits:
  • Quenched Cell permeable dye
  • Can be used with Cell Lysates, Tissue Homogenates
  • One Step, No wash Homogenous assay.
  • Adaptable to High throughput assay platforms
  • Can monitor multiple time points to follow real time kinetics
  • Non-destructive cell based assay allows monitoring of additional parameters
  • Applications - Fluorescence plate reader / Flow cytometer / Fluorescence Microscope
Introduction:
A new novel probe, Hydroxyphenyl fluorescein (HPF), developed by Tetsuo Nagano et. al. (1), is a highly selective probe for the detection of highly Reactive Oxygen Species (hROS). It is a cell permeable highly sensitive fluorescent probe for hydroxyl radical (OH), and peroxynitrite (ONOO-) detection. It has little reactivity towards other hROS such as: hypochlorite (-OCl), singlet oxygen (021), superoxide (02-•), hydrogen peroxide (H202), nitric oxide (NO), and alkyl peroxide (RO2) (see table below)1.
Assay Principle:
Reactivity:
Reactivity Profile of HPF:
ROS (RFU)
 
HPF (RFU)
Ex:499 Em:515
 
DCFH-DA (RFU)
Ex:500 Em:520
 
Hydroxyl Radical: OH
 
730 7400
Peroxynitrite: ONOO- 120
 
6600
Hypochlorite: -OCl 6 86
Oxygen Radical: 1O2 5 26
Superoxide: O2-• 8 67
Hydrogen Peroxide : H202 2 190
Nitric Oxide: NO 6 150
Alkylperoxyl Radical: ROO 17 710
Autoxidation 1 2000
The following kits are available:
Catalog #
 
Contents Size* Price
FLHPF 100-2
 
HPF 1 vial 150 Tests * €195
Dilution of HPF
 
Volume of test Numer of tests
1:500 (10mM final)
 
0.2 mL 147
1: 1000 (5mM final) 0.2mL 294